Problem of unit for thread's period
During the generation of code for the example osek-modes_without_datareference, the initialization of period value is wrong for all periodic threads: the value is given in milliseconds in place of microseconds.
This error seems to come from the call to the function getScaledValue of the AADL meta-model.